Abstract

We describe a system to measure combustion instabilities in gas turbine engines used for electrical power generation. The sensor is an extrinsic fiber optic Fabry-Perot interferometer packaged in a 6mm diameter probe that is permanently positioned within the engine near the combustor.

© 2018 The Author(s)

PDF Article

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator