Towards Broadband Multi-species Trace Gas Detection Using a Mid-infrared Supercontinuum Source

Not Accessible

Your library or personal account may give you access

Abstract

We present mid-infrared trace gas sensing based on a supercontinuum source combined with direct absorption spectroscopy and sum-frequency upconversion, showing broadband detection with a 10-4 Hz-1/2 noise equivalent absorbance sensitivity.

© 2018 The Author(s)