Abstract
We present a low-confinement Si waveguide for 4.26 μm wavelength and apply it to sense CO2 concentrations down to 0.1 %. We demonstrate the highest reported waveguide sensitivity to CO2: 44% of the free-space sensitivity
© 2019 The Author(s)
PDF ArticleMore Like This
Pen-Sheng Lin, Arne Quellmalz, Po-Han Huang, Shayan Parhizkar, Nour Negm, Stephan Suckow, Floria Ottonello-Briano, Max C. Lemme, Frank Niklaus, and Kristinn B. Gylfason
SF4O.1 CLEO: Science and Innovations (CLEO:S&I) 2022
U. Griškevičiūtė, R.W. Millar, K. Gallacher, L. Baldassarre, M. Sorel, M. Ortolani, and D.J. Paul
STh1N.2 CLEO: Science and Innovations (CLEO:S&I) 2019
Mark Stephen, James Abshire, Jeffrey Chen, Kenji Numata, Stewart Wu, Brayler Gonzales, Michael Rodriguez, Graham Allan, William Hasselbrack, Anthony Yu, Molly Fahey, Jeffrey Nicholson, Anand Hariharan, William Mamakos, and Brian Bean
STu4A.2 Optical Sensors (Sensors) 2019