Abstract

Eye box enlargement in augmented reality (AR) head mounted display (HMD) system is a crucial issue. Expansion of the eye-box formed from the holographic image combiner can be achieved by exploiting Bragg mismatch condition in holographic optical elements (HOEs). In this paper, analysis of chromatic aberration in holographic image combiner is carried out with experimental set up and results when Bragg condition is not satisfied.

© 2018 The Author(s)

PDF Article

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.