Abstract

3-node integrated packet/circuit Ethernet network experiment demonstrates aggregation and add/drop of 10Gb/s fronthaul links on a 100Gb/s path. Bounded 5.9µs maximum end-to-end delay and 1.24µs PDV is achieved, even when combining with less delay-sensitive traffic.